Product Model
|
SFP+CO-10A-003-RJ45
|
Manufacturer brand
|
SINOCONEC
|
Package Type
|
SFP+
|
Interface Type
|
RJ45
|
Max Data Rate
|
10.3Gbps
|
10G Effective transmission distance(OM4)
|
100m
|
Hot-Pluggable SFP
|
YES
|
Operating voltage
|
3.3V
|
Power Consumption
|
1.5W
|
Protocols
|
SFP MSA SFF-8472
|
Operating Temperature(Commercial)
|
-10℃~+70℃
|
Storage Temperature(Commercial)
|
-40℃~+85℃
|
Operating Temperature(Industrial)
|
-40℃~+85℃
|
Storage Temperature(Industrial)
|
-40℃~+85℃
|
SINOCONEC continues to invest in optical transceiver production, covering a full range of optical transceiver such as 1*9, SFP, 10G, 25G, 100G, 200G, 400G, 800G GPON/EPON/XG/XGSPON OLT transceiver. At the same time, our company provides TOSA, ROSA, BOSA semi-finished device solutions for the downstream peer. SINOCONEC's production line has a daily production capacity of 10,000 optical transceivers and 20,000 optical devices. In addition, SINOCONEC's optical transceiver have industry-leading high temperature resistance and anti-interference capability, and are widely used in computing centers, operators, traffic security, power facilities and other industries.
The SINOCONEC SFP+ Copper 10GBASE-T RJ45 transceiver Small Form Pluggable (SFP ) modules, with a reach of 30 meters, adhere to the SFP Multi Source Agreement (MSA). They are fully compliant with the 10GBASE-T, 1000BASE-T, and 100BASE-TX standards outlined in IEEE 802.3an, 802.3ab, and 802.3au.
Support 10GBASE-T operation in host systems and auto-negotiation to lower speed | Support RX_LOS as Link indication function | ||||||||
Hot-Pluggable SFP Footprint | Compact RJ-45 connector assembly | ||||||||
Compliant with SFP MSA |
Operating case temperature:
Extended:-10℃~70℃
Industrial: -40℃~85℃
|
||||||||
Safety Certification: TUV/UL/FDA |
10G BASE-T IEEE 802.3an | 5GBASE-T 802.3bz | ||||||||
2.5GBASE-T 802.3bz | 1000BASE-T IEEE 802.3ab | ||||||||
100BASE-TX IEEE 802.3u | 5GBASE-T Broadcom MGBASE-T | ||||||||
2.5GBASE-T Broadcom MGBASE-T |
Part No. | Data Rate | Media Type | Distance | Connector | Temperature | |||
SNC-SFP+CO-10A-003-RJ45 | 10G | CAT6A/CAT7 | 30m | RJ45 | Extended | |||
5G | CAT6 or better | 50m | RJ45 | Extended | ||||
2.5G | CAT5E or better | 100m | RJ45 | Extended | ||||
1G | CAT5E or better | 100m | RJ45 | Extended | ||||
100M | CAT5E or better | 100m | RJ45 | Extended |
Parameter | Symbol | Min. | Typ. | Max. | Units | |||
Maximum supply voltage | Vcc | -0.5 | 4.0 | V | ||||
Storage temperature | TS | -40 | 85 | °C |
Parameter | Symbol | Min | Typ. | Max | Units | |||
Operating case temperature | Tc | SNC-SFP+CO-10A-003-RJ45 | -10 | 70 | °C | |||
Supply voltage | Vcc | 3.15 | 3.3 | 3.45 | V |
Parameter | Symbol | Min | Typ. | Max | Units | Notes/Conditions | ||
+3.3 Volt Electrical Power Interface |
||||||||
Supply Current |
Icc | 710 | mA | SNC-SFP+CO-10A-003-RJ45 | ||||
Input voltage | Vcc | 3.15 | 3.3 | 3.45 | V | |||
Low-Speed Signals, Electronic Characteristics |
||||||||
SFP output low | VOL | 0 | 0.5 | V | 4.7k to 10k pull-up to host_Vcc, measured at host side of connector | |||
SFP output high | VOH | Vcc–0.5 | Vcc+0.3 | 4.7k to 10k pull-up to host_Vcc, measured at host side of connector | ||||
SFP input low | VIL | 0 | 0.4 | 4.7k to 10k pull-up to Vcc, measured at SFP side of connector | ||||
SFP input high | VIH | 2.8 | Vcc+0.3 | 4.7k to 10k pull-up to Vcc, measured at SFP side of connector | ||||
High-Speed Electrical Interface, Transmission Line-SFP |
||||||||
Tx output impedance | Zout,TX | 100 | Ohm | |||||
Rx input impedance | Zin,RX | 100 | Ohm | |||||
High-Speed Electrical Interface, Host-SFP |
||||||||
CML Inputs(Differential) |
Vin | 250 | 1200 | mV | AC coupled inputs | |||
CML outputs(Differential) | Vout | 350 | 800 | mV | CML outputs(Differential) | |||
Rise/Fall time | Tr,Tf | 20 | psec | 20%-80% | ||||
Tx input impedance | Zin | 100 | Ohm | Differential ended | ||||
Rx output impedance | Zout | 100 | Ohm | Differential ended |
Pin No. | Name | Function | Plug Seq. | Notes | ||||
1 | VeeT | Transmitter ground | 1 | |||||
2 | TX Fault | Transmitter fault indication | 3 | Not used | ||||
3 | TX Disable | Transmitter disable | 3 | Note1 | ||||
4 | MOD-DEF2 | Module definition 2 | 3 | Note2 | ||||
5 | MOD-DEF1 | Module definition 1 | 3 | Note2 | ||||
6 | MOD-DEF0 | Module definition 0 | 3 | Note2 | ||||
7 | RS0 | No connection required | 3 | |||||
8 | LOS | Loss of signal | 3 | RX_LOSS | ||||
9 | RS1 | No connection required | 1 | |||||
10 | VeeR | Receiver ground | 1 | |||||
11 | VeeR | Receiver ground | 1 | |||||
12 | RD- | Inv. Received data out | 3 | |||||
13 | RD+ | Received data out | 3 | |||||
14 | VeeR | Receiver ground | 1 | |||||
15 | VccR | Receiver power | 2 | |||||
16 | VccT | Transmitter power | 2 | |||||
17 | VeeT | Transmitter ground | 1 | |||||
18 | TD+ | Transmit data in | 3 | |||||
19 | TD- | Inv. Transmit data in | 3 | |||||
20 | VeeT | Transmitter ground | 1 |

SINOCONEC Copper SFPs support the 2-wire serial communication protocol outlined in the SFP MSA, These SFP use a 128 byte EEPROM with an address of A0H.
Accessing Serial ID Memory uses the 2 wire address 1010000X (A0H). Memory Contents of Serial ID are shown in Table 1.
Table 1 Serial ID Memory Contents |
||||||||
Data Addr | Field Size(Byte) | Name of Filed | Description of Field | Coded Value | Hex | |||
BASE ID FIELDS | ||||||||
0 | 1 | Identifier | Typeof serial transceiver | SFP+ | 03 | |||
1 | 1 | Ext.Identifier | Extended identifier of type of serial transceiver | MOD_DEF 4 | 04 | |||
2 | 1 | Connector | Code for connector type | RJ45 | 22 | |||
3 | 8 | Transceiver | 10G Ethernet compliance codes & infiniband compliance codes | 00 | ||||
4 | Part of SONET compliance codes | 00 | ||||||
5 | SONET compliance codes | 00 | ||||||
6 | Ethernet compliance codes | 00 | ||||||
7 | Fiber channel link length & part of Fibre channel technology |
00 | ||||||
8 | Part of fiber channel transmitter technology | 00 | ||||||
9 | Fiber channel transmission media | 00 | ||||||
10 | Fiber channel speed | 00 | ||||||
11 | 1 | Encoding | Code for high speed serial encoding algorithm | 64B/66B | 06 | |||
12 | 1 | BR, Nominal | Nominal signalling rate, units of 100MBd. | 10.3Gbps | 67 | |||
13 | 1 | Rate Identifier | Typeof rate select functionality | 00 | ||||
14 | 1 | Length(SMF,km) | Link length supported for single mode fiber, units of km | 00 | ||||
15 | 1 | Length (SMF) | Link length supported for single mode fiber, units of 100 m |
00 | ||||
16 | 1 | Length (50um) | Link length supported for 50um OM2 fiber, units of 10 m | 00 | ||||
17 | 1 | Length (62.5um) | Link length supported for 62.5um OM1 fiber, units of 10 m | 00 | ||||
18 | 1 | Length (Copper) | Link length supported for copper, units of meters | 30m | 1E | |||
19 | 1 | Length (OM3) | Link length supported for 50um OM3 fiber, units of 10 m | 00 | ||||
20 | 16 | Vendor name | Vendor name (ASCII) | E | 45 | |||
21 | o | 6F | ||||||
22 | p | 70 | ||||||
23 | t | 74 | ||||||
24 | o | 6F | ||||||
25 | l | 6C | ||||||
26 | i | 69 | ||||||
27 | n | 6E | ||||||
28 | k | 6B | ||||||
29 | 20 | |||||||
30 | 20 | |||||||
31 | 20 | |||||||
32 | 20 | |||||||
33 | 20 | |||||||
34 | 20 | |||||||
35 | 20 | |||||||
36 | 1 | Transceiver | Extended compliance codes | 10GBASE-T Short Reach (30 meters) |
1C | |||
37 | 3 | Vendor OUI | SF P vendor IEEE company ID | 00 | ||||
38 | 00 | |||||||
39 | 00 | |||||||
40 | 16 | Vendor PN | Part number provided by vendor (ASCII) | E | 45 | |||
41 | O | 4F | ||||||
42 | L | 4C | ||||||
43 | T | 54 | ||||||
44 | - | 2D | ||||||
45 | C | 43 | ||||||
46 | 9 | 39 | ||||||
47 | 6 | 36 | ||||||
48 | - | 2D | ||||||
49 | 0 | 30 | ||||||
50 | 2 | 32 | ||||||
51 | 20/2D | |||||||
52 | 20/49 | |||||||
53 | 20 | |||||||
54 | 20 | |||||||
55 | 20 | |||||||
56 | 4 | Vendor rev | Revision level for part number provided by vendor (ASCII) | 1 | 31 | |||
57 | . | 2E | ||||||
58 | 0 | 30 | ||||||
59 | 20 | |||||||
60 | 2 | Wavelength | Laser wavelength | 00 | ||||
61 | 00 | |||||||
62 | 1 | Reserved | 00 | |||||
63 | 1 | CC_BASE | Check code for base ID fields (addresses 0 to 62) | Note3 | xx | |||
64 | 2 | Options | Indicates which optional transceiver signals are implemented | TX_DISABLEsignal,Rx_LOS | 00 | |||
65 | 12 | |||||||
66 | 1 | BR, max | Upper bitrate margin, units of % | 00 | ||||
67 | 1 | BR, min | Lower bitrate margin, units of % | 00 | ||||
68 | 16 | Vendor SN | Serial number provided by vendor(ASCII) | x | xx | |||
69 | x | xx | ||||||
70 | x | xx | ||||||
71 | x | xx | ||||||
72 | x | xx | ||||||
73 | x | xx | ||||||
74 | x | xx | ||||||
75 | x | xx | ||||||
76 | x | xx | ||||||
77 | x | xx | ||||||
78 | 20 | |||||||
79 | 20 | |||||||
80 | 20 | |||||||
81 | 20 | |||||||
82 | 20 | |||||||
83 | 20 | |||||||
84 | 8 | Date code | Vendor’s manufacturing date code | Year | xx | |||
85 | Year | xx | ||||||
86 | Month | xx | ||||||
87 | Month | xx | ||||||
88 | Day | xx | ||||||
89 | Day | xx | ||||||
90 | 20 | |||||||
91 | 20 | |||||||
92 | 1 | Diagnostic monitoring type | Typeof diagnostic monitoring is implemented | diagnostic monitoring is not implemented |
00 | |||
93 | 1 | Enhanced options | Optional enhanced features are implemented | Optional enhanced features are not implemented |
00 | |||
94 | 1 | SFF-8472 Compliance | Revision of SFF-8472 the transceiver complies with | Digital diagnostic functionality not included or undefined |
00 | |||
95 | 1 | CC_EXT | Check code for the extended ID fields (addresses 64 to 94) | Note4 | xx |